Description:
General Specifications
Tunnel Size: 1000 (W) ><1000 (H) mm
Conveyor Speed: 0.22m/s
Conveyor Max Load: 250 kg
Single inspection dosage: < 1.5 mGy
Fire Resolution: 0.101mm metal line
Steel Penetration: 38MM
Film Safety: For ISO 1600
X-RAY GENERATOR
Orientation: Downward
Tube Curran: 0.4~0.7MA (adjustable)
Anode Voltage: 100~160KV (adjustable)
Angle: 60°
Generator cooling/working periods
Sealed oil bath with forced air /100%
OPERATING Environment
Storage Temperature: -20C to 60C
Operating Temperature: 0C to 45C
Relative Humidity:
20 to 95%; non-condensing
System Power: 220 VAC (+-10%) 50+-3HZ
Power wastage: 1.0 KW (Max)
Noise<65DB
X-RAY Sensor.
L-shaped array detector 24bit
Multi-energy: High/low energy: Switch from high energy to low energy
Color material identification: Organic objects in orange, inorganic objects in blue,
mixture in green